§ 66-315. Performance development standards for R-6 district.  


Latest version.
  • (a)

    Density standards and setbacks required in the R-6 district may be amended as set forth in this section for a newly developed subdivision that provides the following infrastructure and meets the following requirements:

    (1)

    Provides:

    a.

    Paved roads.

    b.

    Curb and gutter.

    c.

    A municipal or community water system.

    d.

    A municipal sewer system.

    e.

    Underground utilities.

    f.

    Streetlights.

    (2)

    Contains undivided areas designated as open space that are available for all owners of property in the subdivision.

    (3)

    Homeowners are members of a homeowners' association.

    (4)

    Minimum size of the subdivision is five acres.

    (b)

    For the subdivisions meeting the requirements set forth in subsection (a) of this section, a density limit of seven units per acre shall apply in lieu of individual minimum lot sizes. Setbacks and lot criteria shall be as follows:

    (1)

    A 25-foot setback shall apply between any building or structure constructed within the subdivision where such subdivision adjoins a different zoning district.

    (2)

    Front yard setback shall be 15 feet.

    (3)

    Setback between structures shall be ten feet and shall be measured from the face of the structures, provided, that roof overhangs, eves and projections of 18 inches or less from the face of the structure shall be allowed to project into the required setback area.

    (4)

    Minimum lot width for individual structures shall be 40 feet.

(Code 2003, § 30-315; Ord. No. 02-21, § 1(19.136), 6-20-2002; Ord. No. 04-36, § 1, 11-18-2004)